APC Smart-UPS SRT 6000VA 230V

  • Output power capacity    6.0kWatts / 6.0kVA
  • Nominal Output Voltage    230V
  • Output Voltage Distortion    Less than 2%
  • Output Frequency (sync to mains)     50/60Hz +/- 3 Hz
  • Load Crest Factor     3 : 1
  • Topology      Double Conversion Online
  • Waveform type    Sine wave
  • Bypass   Internal Bypass (Automatic and Manual)
  • Nominal Input Voltage     230V
  • Input frequency       40 – 70 Hz (auto sensing)
  • Input Connections     Hard Wire 3 wire (1PH+N+G)
  • Input voltage range for main operations      160 – 275V
  • Input voltage adjustable range for mains operation     100 – 275 (half load)V
  • Battery type   Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Typical recharge time   1.5hour(s)
  • Nominal Battery Voltage     192V
  • Interface Port(s)     RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB
  • Control panel        Multi-function LCD status and control console
  • Audible Alarm     Audible and visible alarms prioritized by severity
  • Emergency Power Off (EPO)      Yes
  • Surge energy rating     80Joules
  • 1 Year Warranty
Out of stock

Apc 3kva Ups SMC3000I

APC Smart-UPS

Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.

  • Cold-start capable
    Provides temporary battery power when the utility power is out.
  • Green mode
    Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • High online efficiency
    Reduces utility costs, generates less heat.
  • LCD Status Display
    Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
  • Pure sine wave output on battery
    Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.
Audible alarms

Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators

Quickly understand unit and power status with visual indicators.
Disconnected battery notification

Warns when a battery is not available to provide backup power.
Network manageable

Provides remote power management of the UPS over the network.
Serial connectivity

Provides management of the UPS via a serial port.
USB connectivity

Provides management of the UPS via a USB port (not available on all models).