Smarter productivity with ability to tailor to your specific application needs Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.
Liebert PSI is designed and packaged for flexibility and high availability 0.9 output power factor for active power maximization Up to 4 minutes backup time at full load, more than enough to grant orderly OS shutdown User replaceable, hot-swap batteries for increased availability Versatile rack-tower design which adapts to all types of installations Rotatable LED display which adapts to both rack and tower mounting Mounting hardware and shutdown software included in UPS package for increased ease of use
APC Easy UPS SRV 3000VA 230V (SRV3KI) High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions APC Easy UPS SRV 3000VA 230V High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions Includes: Basic UPS signaling RS-232 cable, CD with software, USB cable, User Manual Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. ECO Mode The operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Output power capacity 2.1kWatts / 3.0kVA Nominal Output Voltage 230V Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 50 Hz Waveform type Sine wave Nominal Input Voltage 230V Input frequency 47 – 63 Hz Input Connections IEC-320 C20 Input voltage range for main operations 180 – 287V Input voltage adjustable range for mains operation 170 – 300V Typical recharge time 3hour(s) Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays Surge energy rating 300Joules 1 Year Warranty
equipment with Boost and Buck AVR to stabilize the input voltage Microprocessor control guarantees high reliability Provides AC overload Protection Auto-restart with AC recover Compact size, lightweight Off Mode Charging Overload protection and alarm Small Routers, Bridges, and Hub
APC Smart-UPS SRT 8000VA 230V High density, double-conversion on-line power protection with scalable runtime Includes: CD with software, Documentation CD, Installation guide, Temperature Probe, USB cable, Warranty card, Web/SNMP Management Card 10/100 BaseT Connection Connect the device to a network using a 10 or 100 BaseT connection Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. LCD graphics display Text and mimic diagrams that display modes of operation, system parameters and alarms.
The Vertiv™ LiebertGXT5 UPS is an online double conversion UPS solution which offers premium power outage protection and continuous power conditioning in a compact and flexible deployment system. The LiebertGXT5 single phase UPS operates with high power efficiency and it is ideally suited to protect critical infrastructure in both centralised and edge network applications. Scalable runtime options with matching external battery cabinets offer additional flexibility when extended uninterrupted power is required. User friendly LCD interface as well as full network management capability, including configuration and remote updates, make this system easy to deploy and simple to maintain. With market leading efficiency and unity power factor operation, the LiebertGXT5 will fill your critical application needs. Sleep well knowing your business is protected by the premium products from Vertiv.
Power 10KVA / 7000W Voltage range 176 ±5VAC~276 ±5VAC, Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing Input phase Single-phase Power factor ≥0.98 Voltage range 220VAC ±1% Output phase Single-phase Frequency 50Hz ±0.2% (battery mode) THD < 2% (Linear load); < 6% (non-Linear load) Overload 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode Crest factor 3:1 (max) Waveform Pure sine wave Transfer time 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) Efficiency ≥88% AC mode 5 cycles turn off the inverter, no transfer to Bypass, provide alarm. Battery mode 5 cycles turn off the inverter, provide an alarm. Bypass mode Input fuse has blown or break action. Battery Model 12V sealed lead acid maintenance-free DC voltage 240VDC Configuration 20x 12V/8.2AH Backup time 13min (half load) / 5min (full load) Charge current 1A (standard unit) / 5A (long time unit) Recharge time 90%
WSTRTUP-EZ-30 Features Start-Up Service 5X8 for (1) Easy UPS 3S 30kVA UPS A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution Functional verification During each Preventive Maintenance visit, our Certified Field Service Engineers will run tests to verify your system is functioning correctly in all operational modes, stopping problems before they start. Installation verification Once the equipment is assembled, an APC Certified Field Service Engineer will verify all connections within the system have been made according to factory specification, and that it is functioning correctly in all modes of operation, ensuring optimal performance and extending the life of the product. Labor and travel expenses included Travel and labor expenses are included in most service contracts. Please see the statement of work for the service specifics. Logistics coordination APC will coordinate the logistics of
Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Audible alarms Provides notification of changing utility power and UPS power conditions Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). Cold-start capable Provides temporary battery power when the utility power is out. Disconnected battery notification Warns when a battery is not available to provide
Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Advanced Safety Features Safeguard your Home UPS from overloads, excessive mains voltages, short circuits, installation mishaps and battery damage due to low voltage situations.
Output power capacity 6.0kWatts / 6.0kVA Nominal Output Voltage 230V Output Voltage Distortion Less than 2% Output Frequency (sync to mains) 50/60Hz +/- 3 Hz Load Crest Factor 3 : 1 Topology Double Conversion Online Waveform type Sine wave Bypass Internal Bypass (Automatic and Manual) Nominal Input Voltage 230V Input frequency 40 – 70 Hz (auto sensing) Input Connections Hard Wire 3 wire (1PH+N+G) Input voltage range for main operations 160 – 275V Input voltage adjustable range for mains operation 100 – 275 (half load)V Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Typical recharge time 1.5hour(s) Nominal Battery Voltage 192V Interface Port(s) RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB Control panel Multi-function LCD status and control console Audible Alarm Audible and visible alarms prioritized by severity Emergency Power Off (EPO) Yes Surge energy rating 80Joules 1 Year Warranty
The Vertiv Liebert GXT4 UPS, with a capacity of 3000VA/2700W, is a compact and reliable solution for maintaining the health and availability of your IT infrastructure. Using on-line, double-conversion technology, the Vertiv Liebert GXT4 UPS protects equipment from the full range of power disturbances, including sags, surges and noise, without drawing on battery power, extending battery life and minimizing replacements. The UPS runs on 230V AC power and includes hot-swappable batteries as well as all hardware for installing it as a tower or in an equipment rack. It is ENERGY STAR qualified and includes selectable eco-mode that enhances efficiency during off hours. With outstanding performance and reliability, the Vertiv Liebert GXT4 is the UPS of choice for applications with zero tolerance for downtime.
FEATURES OF LIEBERT PSP UPS 650VA 230V - PSP650MT3-230U: A standby UPS design with a Step Wave output USB communication port and MultiLink software Minimum of three minutes of battery runtime at full resistive Load Data-Line (RJ-45) Surge Protection
PNET1GB Features APC ProtectNet standalone surge protector for 10/100/1000 Base-T Ethernet lines Protects an Ethernet data port from damaging surges. Compatible with Power over Ethernet (PoE) and 10/100/1000 Base-T networks. Catastrophic Event Protection SurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges. ProtectNet Features & Benefits Protection Fail Safe Mode Most other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply
Liebert PSI-XR 2200VA is a compact, line-interactive UPS system designed especially for IT applications such as network closets and small data centers. The flexible design of Liebert PSI-XR allows the unit to be configured as a self-standing tower or to be rack-mounted within a 2U space. It is available in four capacities.
Power 6KVA / 4200W Voltage range 176 ±5VAC~276 ±5VAC Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing Input phase Single-phase Power factor ≥0.98 Voltage range 220VAC ±1% Output phase Single phase se Frequency 50Hz ±0.2% (battery mode) THD < 2% (Linear load); < 6% (non-Linear load) Overload 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode Crest factor 3:1 (max) Waveform Pure sine wave Transfer time 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) Efficiency ≥88% AC mode 5 cycles turn off the inverter, no transfer to Bypass, provide alarm. Battery mode 5 cycles turn off the inverter, provide an alarm. Bypass mode Input fuse has blown or break action. Battery Model 12V sealed lead acid maintenance-free DC voltage 240VDC Configuration 20x 12V/8.2AH Backup time 20min (half load) / 7min (full load) Charge current 1A (standard unit) / 5A (long time unit) Recharge
KEY FEATURES Capacity: 10kVA; Power: 9kW Battery Voltage: 384VDC (32 x 12V) – Batteries not included Model: Mercury EP10K Technology: Double Conversion Online Load Bus Synchronization (LBS) Function Advanced IGBT Rectifier To Have Low THDi & High PF LCD Indication & Audible Alarm Function Front Accessible Module Design For Ease Of Maintenance Wide Input Voltage Range Intelligent Battery Management Flexibility Of Configurable Battery Bank Parallel Redundancy Surge, Short Circuit & Overload Protection Low Audible Noise; Low Output Voltage Cold Start; ECO Mode SPECIFICATIONS Size (L x W x H cm) mm: 930 x 700 x 1390 Weight (kg) 215 Colour: Black Product Warranty: One Year Warranty
This true on-line double conversion UPS system is available in larger capacity models of 5 kVA - 10 kVA, featuring integrated maintenance bypass as well as optional extended battery runtime. The Liebert GXT4 UPS is designed for use in either rack or tower configurations. It maintains a compact footprint in all ratings, with 5000 - 6000 VA models with a height of 5 U, and 10000 VA with a height of 6 U, as well as a short depth of Flexibility: Rotatable multi-language LCD display panel Compact 5Us or 6Us height and short depth ( Automatic frequency sensing Frequency conversion capability Rack & tower mounting flexibility User replaceable hot-swappable internal batteries Extended backup time with additional battery cabinets Liebert IntelliSlot® communication port available Includes Windows®-based configuration program Built-in USB communication ports for use with Liebert MultiLink™ automated shutdown software Built-in closure signals
Capacity 3KVA / 2400W Phase Single Phase Input voltage 115VAC(±5) ~ 295VAC(±5) if load ≤ 70%; 160VAC(±5) ~ 295VAC(±5) if load ≥ 70% Frequency 46 ~ 54(50Hz)±0.5Hz; 56 ~ 64(60Hz)±0.5Hz auto-sensing Input power factor ≥ 0.97 Output voltage 220/230VAC ± 2% Frequency 50Hz / 60Hz ± 0.2% THD < 3% (linear load); < 5% (non linear load) Overload capability > 110%, 30s turn to bypass mode; > 150%, 300ms turn to bypass mode Crest factor 3:1 (max) AC Mode: 10 cycles, when voltage lower than rated 30%, and inrush current higher than rated 70%, turn off the inverter, no transfer to bypass, give alarm battery Mode: 10 cycles, when voltage lower than rated 30% and inrush current higher than rated 70%, turn off the inverter, give an alarm bypass Mode: Input fuse blew or break action Waveform Pure sine wave Transfer time 0ms between AC mode & Bypass mode 4ms
Line Interactive UPS topology includes technology that enables the UPS to interact with incoming AC voltage and correct minor voltage fluctuations without switching to battery. This extends the life of the battery and is essential in areas where frequent power fluctuations are common. The Mercury UPS 650VA- 3.0KVA Maverick Line Interactive UPS ideal for Personal Computers […]