MERCURY DEEP CYCLE BATTERY 100AH

  • Specification
  • 20 Hour Rate      100AH
  • 10 Hour Rate      92AH
  • 5 Hour Rate        80AH
  • Overvoltage Restoration              41AH
  • Internal Resistance Fully Charged Battery             4.5m
  • Self Discharge:
  • Capacity after 3 Month Storage 91%
  • Capacity after 6 Month Storage 81%
  • Capacity after 12 Month Storage               60%
  • Max Discharge Current  800A (5S)
  • Terminal              M3
  • Cycle     Initial Charging Less than 30A
  • Float      Voltage 14.4 ~ 14.7V/77°F (25°C)
  • Voltage 13.5 ~ 13.8V/77°F (25°C)
  • Dimension (WxDxH) mm              208 X 407 X 174
  • Net Weight (kg)                30

MERCURY UPS REPLACEMENT BATTERY 7.5AH

TECHNICAL SPECIFICATIONS FOR MERCURY ELITE 7.5AH 12V UPS BATTERY

 

20 Hour Rate 7.5Ah
10 Hour Rate 6.9Ah
5 Hour Rate 6.0Ah
1 Hour Rate 4.5Ah
Internal Resistance :
Fully Charged Battery 24mΩ
Self Discharge :
Capacity after 3 Month Storage 91%
Capacity after 6 Month Storage 81%
Capacity after 12 Month Storage 60%
Max Discharge Current 112.5A(5S)
Terminal F1/F2
Charge (Constant Voltage) :
Cycle Initial Charging Current less than 2.25A
Voltage 14.4~14.7V/7°F(25°C)
Physical :
Dimension (WxDxH) mm 225 X 523 X 240
Net Weight (kg) 56.5

Mercury 5KVA 48V Solar Hybrid

Features

  • High-frequency switching technology, compact size and lightweight
  • Pure sine wave output for a wide range of applications
  • Build-in solar charger controller with MPPT technology to optimize the power utilization (some
    models don’t have this option)
  •  Efficient DC-to-AC conversion minimizing energy loss
  •  Standby Charging Mode enables battery charging even when the unit is switched off
  •  Intelligent cooling fan control
  •  Input/ output isolated design for the maximum operation safety
  • LCD displays for detailed status
  • Configurable AC input voltage range and priority for AC or PV input
  • Supports Home Appliances / Office Equipment/ Lighting Equipment/ Motor-based Equipment
    (such as Fan, Air-Conditioner, Washing Machines etc)
  •  Input low voltage / Overload / Short circuit / Low battery alarm / Input over-voltage / Over
    temperature protection.
  • Supports both rack and wall-mount installation

Specification

Inverter Mode

  • Rated Power: 5KVA/5.0KW
  • DC Input :   48Vdc, 114A
  • AC Output:  230Vac, 50/60Hz, 21.7A
  • AC Charger Mode
  • AC Input :220 240Vac, 50/60Hz, 31.6A
  • DC Output : 54.8Vac,  35A/ 15A
  • AC Output : 230Vac, 50/ 60Hz, 21.7A

Solar Charger Mode

  • Max Charger Current 80A
  • System DC Voltage Range  48Vdc
  • Operating Voltage Range: 60  – 150Vdc
  • PV Optimal Work Voltage Range: 70 – 145 Vdc
  • Max Solar Voltage (VOC) : 150Vdc

MERCURY 3KVA SPIRIT PLUS SOLAR

1. High-frequency switching technology for compact size and light weight

2. Pure sine wave output for wide range of applications and harsh environment

3. Build-in solar charger controller with MPPT technology to optimize the power utilization

4. High efficient DC-to-AC conversion minimizing energy loss

5. Standby Charging Mode enables battery charging even when the unit is switched off

6. Intelligent cooling fan control

7. Input/output isolated design for the maximum operation safety

8. LCD displays comprehensive operation status

9. Configurable AC input voltage range and priority for AC input or PV input

10. Supports Home Appliances / Office Equipment/ Lighting Equipment/ Motor-based Equipment (such as Fan, Air-Conditioner, Washing Machines)

11.Thorough protections: Input low voltage / Overload / Short circuit / Low battery alarm / Input over voltage / Over temperature 12.Supports both rack and wall-mounting set-up for flexible installation

12.Supports both rack and wall-mounting set-up for flexible installation

MERCURY 2KVA 24V SPIRIT PLUS

Inverter Mode

Rated Power : 2KVA/2KW

DC Input :   24Vdc, 110A

AC Output:  230Vac, 50/60Hz, 12.5A

AC Charger Mode

AC Input :220 240Vac 13.8A

DC Output : 27.1Vac,  25A/ 10A

AC Output : 230Vac, 50/ 60Hz, 12.5A

Solar Charger Mode

Max Charger Current 40A

System DC Voltage Range  24Vdc

Operating Voltage Range: 30 – 75Vdc

PV Optimal Work Voltage Range: 45 – 72 Vdc

Max Solar Voltage (VOC) : 75Vdc

Max PV Input Current : 20A

MERCURY 7.5 KVA SOHO PURE

  • Intelligent long backup model
  • Fully digitized microprocessor control LED
  • Wide input range [90V -275V inverter mode 115V -270V UPS mode]
  • Energy saving function with UPS green mode
  • Cold start function
  • Short circuit and overload protection
  • Compatible with all generators
  • Selectable  charging current 20A and 40A
  • Weight 35kg

What’s in the box:

• 1 x Mercury 7.5kva Inverter
•1 x Black Battery Cable
• 1 x Red Battery Cable
• 1 x User Manual

Good to know:

This product is sold with a one year warranty.

MERCURY 5KVA SOHO PURE SINE

  • Intelligent long backup model
  • Fully digitized microprocessor control LED
  • Wide input range [90V -275V inverter mode 115V -270V UPS mode]
  • Energy-saving function with UPS green mode
  • Cold start function
  • Short circuit and overload protection
  • Compatible with all generators
  • Selectable  charging current 20A and 40A
  • Operating Temperature  0°C-40°C
  • Storage Temperature     -25°C-55°C
  • Relative Humidity  20%-95% (no condensation) <1000m, for elevation above     1000m, derate with reference to Elevation  GB7260.3-2003 4.1.1
  • Weight 35kg

What’s in the box:

• 1 x Mercury 5kva Inverter
• 1 x User Manual

Good to know:

This product is sold with a one year warranty.

MERCURY 2.4KVA MODIFIED SINE WAVE

Model 2.4KVA
Voltage 230VAC
Capacity 2400VA/1440W
Voltage Range 170-280VAC (UPS Mode) 90-280 VAC (INV Mode)
Voltage Regulation(Battery Mode) 230VAC +/-10%
Transfer Time 20 ms Typical
Waveform Modified Sine Wave
Battery Voltage 24V
Floating Charge Voltage 27.00VDC +-0.5
Charge Current 10/20A
Dimensions 330 x 227.8 x 92.5
Net Weight (Kgs) 2.8
Gross Weight (Kgs) 3.3

What’s in the box:

• 1 x Mercury 2.4kva Inverter •1 x Black Battery Cable • 1 x Red Battery Cable • 1 x User Manual

Good to know:

• This product is sold with a one year warranty.

MERCURY 1.2KVA INVERTER MODIFIED SINE

Model 1.2k
Voltage 230VAC
Capacity 1200VA/720W
Voltage Range 170-280VAC (UPS Mode)
90-280 VAC (INV Mode)
Voltage Regulation(Battery Mode) 230VAC +/-10%
Transfer Time 20 ms Typical
Waveform Modified Sine Wave
Battery Voltage 12VDC
Floating Charge Voltage 13.75VDC +-0.25
Charge Current 10/20A
Dimention 330 x 227.8 x 92.5
Net Weight (Kgs) 2.6
Gross Weight (Kgs) 3.1

What’s in the box:

• 1 x Mercury 1.2kva Inverter •1 x Black Battery Cable • 1 x Red Battery Cable • 1 x User Manual

Good to know:

• This product is sold with a one year warranty.

Out of stock

Mercury 20Kva 3 phase In

  • Capacity: 20kVA / 18kW
  • Battery Voltage: 384VDC (32 x 12V,Batteries Not included)
  • Model: Mercury EP20K
  • Technology: Double Conversion Online
  • Load Bus Synchronization (LBS) Function
  • Advanced IGBT Rectifier To Have Low THDi & High PF
  • LCD Indication & Audible Alarm Function
  • Front Accessible Module Design For Ease Of Maintenance
  • Wide Input Voltage Range
  • Intelligent Battery Management
  • Flexibility Of Configurable Battery Bank
  • Parallel Redundancy
  • Surge, Short Circuit & Overload Protection
  • Low Audible Noise; Low Output Voltage
  • Cold Start; ECO Mode
  • Dimensions(WxDxH) mm: 930 x 700 x 1390
  • Weight G/N (kg): 242/266

MERCURY 10KVA ONLINE UPS SINGLE

Power 10KVA / 7000W
Voltage range 176 ±5VAC~276 ±5VAC,
Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing
Input phase Single-phase
Power factor ≥0.98
Voltage range 220VAC ±1%
Output phase Single-phase
Frequency 50Hz ±0.2% (battery mode)
THD < 2% (Linear load); < 6% (non-Linear load)
Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass mode
Crest factor 3:1 (max)
Waveform Pure sine wave
Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)
Efficiency ≥88%
AC mode 5 cycles turn off the inverter, no transfer to Bypass,
provide alarm.
Battery mode 5 cycles turn off the inverter, provide an alarm.
Bypass mode Input fuse has blown or break action.
Battery Model 12V sealed lead acid maintenance-free
DC voltage 240VDC
Configuration 20x 12V/8.2AH
Backup time 13min (half load) / 5min (full load)
Charge current 1A (standard unit) / 5A (long time unit)
Recharge time 90% capacity after 8hrs charging
Communication Interface RS232; SNMP (optional)
Parallel Port Parallel availability for redundancy and load sharing up to three-units
LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass”
LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operation
Noise level ≤ 55dB
Temperature 0~40˚C; 0 ~ 40˚C (storage temperature)
Humidity 0~95% (non-condensing)
Altitude < 1500m
Weight Net/Gross 92/107kg (standard unit); 36/51kg (long time unit)

Mercury 6kva Online UPS Single

Power 6KVA / 4200W
Voltage range 176 ±5VAC~276 ±5VAC
Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing
Input phase Single-phase
Power factor ≥0.98
Voltage range 220VAC ±1%
Output phase Single phase
se
Frequency 50Hz ±0.2% (battery mode)
THD < 2% (Linear load); < 6% (non-Linear load)
Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass mode
Crest factor 3:1 (max)
Waveform Pure sine wave
Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)
Efficiency ≥88%
AC mode 5 cycles turn off the inverter, no transfer to Bypass,
provide alarm.
Battery mode 5 cycles turn off the inverter, provide an alarm.
Bypass mode Input fuse has blown or break action.
Battery Model 12V sealed lead acid maintenance-free
DC voltage 240VDC
Configuration 20x 12V/8.2AH
Backup time 20min (half load) / 7min (full load)
Charge current 1A (standard unit) / 5A (long time unit)
Recharge time 90% capacity after 8hrs charging
Communication Interface RS232; SNMP (optional)
Parallel Port Parallel availability for redundancy and load sharing up to three-units
LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass”
LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operation
Noise level ≤ 55dB
Temperature 0~40˚C; 0 ~ 40˚C (storage temperature)
Humidity 0~95% (non-condensing)
Altitude < 1500m
Weight Net/Gross 89/104kg (standard unit); 34/48kg (long time unit)