Accessories
Browse Categories
- Accessories (136)
- APC by Schneider Electric (56)
- APPLE (6)
- Apricon (1)
- B T E a r p i e c e (6)
- Battery (6)
- BT Speaker (2)
- cable (16)
- Charger (9)
- Crucial (4)
- DATA (6)
- Data Storage (7)
- Dell (18)
- Dell latitude (2)
- Desktops (38)
- Earpiece (6)
- Emerson network power (19)
- Extension Socket (1)
- F i t B a n d Te m p o (3)
- F i t B a n d Te m p o (3)
- F l a s h D r i v e (5)
- HP (80)
- Inverter (7)
- Laptops (55)
- Lenovo (13)
- liebert by vertiv (14)
- Logitech (78)
- Mercury (29)
- Microsoft Software (356)
- Microsoft Store (576)
- microsoft store (1)
- Monitor (25)
- Mouse (2)
- Oraimo (55)
- phone (3)
- power bank (8)
- Power Banks (10)
- Power Products (105)
- Printers and Consumables (1)
- Projectors (21)
- S D C a r d (2)
- Samsung (1)
- Sandisk (2)
- Seagate (4)
- Security Gadgets (15)
- Software (45)
- Software Store (48)
- Solar (2)
- Solid State Drives (6)
- Speaker (73)
- Stabilizer (7)
- Surge Protector (1)
- tablet (1)
- Toshiba (14)
- Transcend (1)
- Uncategorized (3)
- UPS (58)
- VILLAON (6)
- VILLAON BT Speaker (2)
- Western Digital (2)
- windows (1)
Filters
Filter by price
Filter by Size
Newsletter
MERCURY 30KVA 3-PHASE FULLY AUTOMATIC
Specifications
Capacity 30 KVA
AC INPUT
Voltage range 277 V ~ 433 V
Frequency range 50/60 Hz
Phase Three phase+ N + G
AC OUTPUT
Voltage: 380 V / 400V
Voltage: regulation accuracy ± 3%
Waveform: Sinusoidal
Efficiency: 96%
Power factor: 0.8
Distortion: No additional waveform distortion
Response time: ± 10% varies< 1 s
Over-voltage protection: Output phase voltage 433 V ± 5 V
Under-voltage: Output phase voltage 316 V ± 5 V
Other protections: Start-up delay -mechanical failure -over-current -short-circuit -phase order (three phase) -lack-phase (three phase) -over temperature
Mercury 6kva Online UPS Single
Power | 6KVA / 4200W |
Voltage range | 176 ±5VAC~276 ±5VAC |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing |
Input phase | Single-phase |
Power factor | ≥0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single phase |
se | |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) |
Efficiency | ≥88% |
AC mode | 5 cycles turn off the inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off the inverter, provide an alarm. |
Bypass mode | Input fuse has blown or break action. |
Battery Model | 12V sealed lead acid maintenance-free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 20min (half load) / 7min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three-units |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ≤ 55dB |
Temperature | 0~40˚C; 0 ~ 40˚C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 89/104kg (standard unit); 34/48kg (long time unit) |
MERCURY 10KVA ONLINE UPS SINGLE
Power | 10KVA / 7000W |
Voltage range | 176 ±5VAC~276 ±5VAC, |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing |
Input phase | Single-phase |
Power factor | ≥0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single-phase |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) |
Efficiency | ≥88% |
AC mode | 5 cycles turn off the inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off the inverter, provide an alarm. |
Bypass mode | Input fuse has blown or break action. |
Battery Model | 12V sealed lead acid maintenance-free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 13min (half load) / 5min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three-units |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ≤ 55dB |
Temperature | 0~40˚C; 0 ~ 40˚C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 92/107kg (standard unit); 36/51kg (long time unit) |
Mercury 20Kva 3 phase In
- Capacity: 20kVAÂ /Â 18kW
- Battery Voltage: 384VDC (32 x 12V,Batteries Not included)
- Model: Mercury EP20K
- Technology: Double Conversion Online
- Load Bus Synchronization (LBS) Function
- Advanced IGBT Rectifier To Have Low THDi &Â High PF
- LCD Indication &Â Audible Alarm Function
- Front Accessible Module Design For Ease Of Maintenance
- Wide Input Voltage Range
- Intelligent Battery Management
- Flexibility Of Configurable Battery Bank
- Parallel Redundancy
- Surge, Short Circuit &Â Overload Protection
- Low Audible Noise; Low Output Voltage
- Cold Start; ECO Mode
- Dimensions(WxDxH) mm: 930 x 700 x 1390
- Weight G/N (kg): 242/266
₦3,047,500.00