MERCURY ONLINE UPS SINGLE PHASE

Capacity 3KVA / 2400W
Phase Single Phase
Input voltage 115VAC(±5) ~ 295VAC(±5) if load ≤ 70%; 160VAC(±5) ~ 295VAC(±5) if load ≥ 70%
Frequency 46 ~ 54(50Hz)±0.5Hz; 56 ~ 64(60Hz)±0.5Hz auto-sensing
Input power factor ≥ 0.97
Output voltage 220/230VAC ± 2%
Frequency 50Hz / 60Hz ± 0.2%
THD < 3% (linear load); < 5% (non linear load)
Overload capability > 110%, 30s turn to bypass mode; > 150%, 300ms turn to bypass mode
Crest factor 3:1 (max)
AC Mode: 10 cycles, when voltage lower than rated 30%,
and inrush current higher than rated 70%,
turn off the inverter, no transfer to bypass,
give alarm battery Mode: 10 cycles, when voltage lower than rated 30%
and inrush current higher than rated 70%,
turn off the inverter, give an alarm bypass Mode: Input fuse blew or break action
Waveform Pure sine wave
Transfer time 0ms between AC mode & Bypass mode
4ms (typical 2.5ms) between Inverter mode & Bypass mode
Efficiency ≥ 87%
Model 12V sealed lead acid maintenance-free
Battery 8x 12V / 7AH
DC voltage 96VDC
Back-up 12min (half load); 5min (full load)
Recharge time 8hours ~ 90% capacity
Charge current 1A(standard unit);6A(long-time unit)
Communication interface RS232 ; SNMP (optional)
LED indication Load or battery capacity
Noise level < 45dB
Temperature 0 ~ 40˚C
Humidity 0% ~ 95% (non-condensing)
Altitude < 1500m
Storage temperature -25 ~ 55˚C
Standard unit (net/gross) 28/30.5 kg
Long-time unit (net/gross) 11/13 kg
Dimension (WxDxH)mm 190 x 468 x 339
Packing(WxDxH)mm 275 x 563 x 446

 

MERCURY SURGE PROTECTOR 6 SOCKETS

Features

• Surge protection• Fire proof design• EMI/RFI protection• Thunder protection• Overload protection• Safe and reliable design

Specification

Input: Nominal Voltage 230VACCurrent 10A (Max)Phase Single phase.

Indication: Power Indicator Neon Type Cable Length 1.8m / 5mInput Plug British Type / Schuko Type.

Output: Socket 6 x Universal Output DC (Total) 4 USB 5V2A• Surge protection• Fire proof design• EMI/RFI protection• Thunder protection• Overload protection• Safe and reliable design.

Environment: Temperature -20˚C~90˚CStorage Temperature -35˚C~95˚CHumidity 0%~95%RH (Non-condensing)200~230VAC Electrical Appliances Power Consumption Chart Hair Dryer 1000WIron 750WFax Machine 55WInkjet Printer 52WPC 180W~300W17” CRT Monitor 80WLCD TV 40W~60WDVD Player 25WVideo Cassette Player 40WMixer 100W~150WRefrigerator 800W~1200W6240U-4U.

MERCURY UPS REPLACEMENT BATTERY 7.5AH

TECHNICAL SPECIFICATIONS FOR MERCURY ELITE 7.5AH 12V UPS BATTERY

 

20 Hour Rate 7.5Ah
10 Hour Rate 6.9Ah
5 Hour Rate 6.0Ah
1 Hour Rate 4.5Ah
Internal Resistance :
Fully Charged Battery 24mΩ
Self Discharge :
Capacity after 3 Month Storage 91%
Capacity after 6 Month Storage 81%
Capacity after 12 Month Storage 60%
Max Discharge Current 112.5A(5S)
Terminal F1/F2
Charge (Constant Voltage) :
Cycle Initial Charging Current less than 2.25A
Voltage 14.4~14.7V/7°F(25°C)
Physical :
Dimension (WxDxH) mm 225 X 523 X 240