Schneider Electric EZC100N3060 circuit breaker Easypact EZC100N – TMD – 60 A – 3 poles 3d – gadgetlot.com
x

Schneider Electric EZC100N3060 circuit breaker Easypact EZC100N – TMD – 60 A – 3 poles 3d

Schneider Electric EZC100N3060 circuit breaker Easypact EZC100N – TMD – 60 A – 3 poles 3d with 15kA breaking capacity.
EZC100F3060 circuit breaker Easypact EZC100F – TMD – 60 A – 3 poles 3d with 10kA breaking capacity.

Free delivery across Nigeria, for order from 100,000 NGN

Read more

 13,409.96 inc. 5% VAT

In Stock
Quantity:

range of product EasyPact
product or component type Circuit breaker
device short name Easypact EZC100N
circuit breaker name Easypact EZC100N
device application Distribution
poles description 3P
protected poles description 3t
network type AC
DC
network frequency 50/60 Hz
[In] rated current 100 A ( 40 °C )
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 250 V DC conforming to IEC 60947-2
550 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity code N
breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 277/480 V AC 50/60 Hz conforming to NEMA AB1
25 kA at 240 V AC 50/60 Hz conforming to NEMA AB1
[Ics] rated service breaking capacity Ics 5 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
Ics 9 kA 380 V AC 50/60 Hz conforming to IEC 60947-2
Ics 12.5 kA 110/130 V AC 50/60 Hz conforming to IEC 60947-2
Ics 12.5 kA 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Ics 2.5 kA 125 V DC conforming to IEC 60947-2
Ics 2.5 kA 250 V DC conforming to IEC 60947-2
Ics 2.5 kA 550 V AC 50/60 Hz conforming to IEC 60947-2
Ics 7.5 kA 400/415 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation Yes conforming to IEC 60947-2
utilisation category Category A
trip unit name TM-D
trip unit technology Thermal-magnetic
trip unit rating 60 A ( 50 °C )
protection type Overload protection
Short-circuit protection
pollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1