Mercury 20Kva 3 phase In

  • Capacity: 20kVA / 18kW
  • Battery Voltage: 384VDC (32 x 12V,Batteries Not included)
  • Model: Mercury EP20K
  • Technology: Double Conversion Online
  • Load Bus Synchronization (LBS) Function
  • Advanced IGBT Rectifier To Have Low THDi & High PF
  • LCD Indication & Audible Alarm Function
  • Front Accessible Module Design For Ease Of Maintenance
  • Wide Input Voltage Range
  • Intelligent Battery Management
  • Flexibility Of Configurable Battery Bank
  • Parallel Redundancy
  • Surge, Short Circuit & Overload Protection
  • Low Audible Noise; Low Output Voltage
  • Cold Start; ECO Mode
  • Dimensions(WxDxH) mm: 930 x 700 x 1390
  • Weight G/N (kg): 242/266

MERCURY 10KVA ONLINE UPS SINGLE

Power 10KVA / 7000W
Voltage range 176 ±5VAC~276 ±5VAC,
Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing
Input phase Single-phase
Power factor ≥0.98
Voltage range 220VAC ±1%
Output phase Single-phase
Frequency 50Hz ±0.2% (battery mode)
THD < 2% (Linear load); < 6% (non-Linear load)
Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass mode
Crest factor 3:1 (max)
Waveform Pure sine wave
Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)
Efficiency ≥88%
AC mode 5 cycles turn off the inverter, no transfer to Bypass,
provide alarm.
Battery mode 5 cycles turn off the inverter, provide an alarm.
Bypass mode Input fuse has blown or break action.
Battery Model 12V sealed lead acid maintenance-free
DC voltage 240VDC
Configuration 20x 12V/8.2AH
Backup time 13min (half load) / 5min (full load)
Charge current 1A (standard unit) / 5A (long time unit)
Recharge time 90% capacity after 8hrs charging
Communication Interface RS232; SNMP (optional)
Parallel Port Parallel availability for redundancy and load sharing up to three-units
LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass”
LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operation
Noise level ≤ 55dB
Temperature 0~40˚C; 0 ~ 40˚C (storage temperature)
Humidity 0~95% (non-condensing)
Altitude < 1500m
Weight Net/Gross 92/107kg (standard unit); 36/51kg (long time unit)

Mercury 6kva Online UPS Single

Power 6KVA / 4200W
Voltage range 176 ±5VAC~276 ±5VAC
Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto-sensing
Input phase Single-phase
Power factor ≥0.98
Voltage range 220VAC ±1%
Output phase Single phase
se
Frequency 50Hz ±0.2% (battery mode)
THD < 2% (Linear load); < 6% (non-Linear load)
Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass mode
Crest factor 3:1 (max)
Waveform Pure sine wave
Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)
Efficiency ≥88%
AC mode 5 cycles turn off the inverter, no transfer to Bypass,
provide alarm.
Battery mode 5 cycles turn off the inverter, provide an alarm.
Bypass mode Input fuse has blown or break action.
Battery Model 12V sealed lead acid maintenance-free
DC voltage 240VDC
Configuration 20x 12V/8.2AH
Backup time 20min (half load) / 7min (full load)
Charge current 1A (standard unit) / 5A (long time unit)
Recharge time 90% capacity after 8hrs charging
Communication Interface RS232; SNMP (optional)
Parallel Port Parallel availability for redundancy and load sharing up to three-units
LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass”
LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operation
Noise level ≤ 55dB
Temperature 0~40˚C; 0 ~ 40˚C (storage temperature)
Humidity 0~95% (non-condensing)
Altitude < 1500m
Weight Net/Gross 89/104kg (standard unit); 34/48kg (long time unit)

MERCURY 30KVA 3-PHASE FULLY AUTOMATIC

Specifications

Capacity 30 KVA

AC INPUT

Voltage range 277 V ~ 433 V

Frequency range 50/60 Hz

Phase Three phase+ N + G

AC OUTPUT

Voltage: 380 V / 400V

Voltage: regulation accuracy   ± 3%

Waveform:  Sinusoidal

Efficiency: 96%

Power factor: 0.8

Distortion: No additional waveform distortion

Response time: ± 10% varies< 1 s

Over-voltage protection: Output phase voltage 433 V ± 5 V

Under-voltage: Output phase voltage 316 V ± 5 V

Other protections: Start-up delay -mechanical failure -over-current -short-circuit -phase order (three phase) -lack-phase (three phase) -over temperature

Mercury 15KVA 3-Phase In/Out AVR

  • Phase: Three Phase
  • Output Voltage: 380V
  • Over-voltage Protection; Low-voltage Protection
  • Display Model: LED / METER
  • Wide Input Voltage Range: 130V ~ 280Vac
  • 6 Steps Transformer Design In Voltage Stabilizing – For that extra reliability
  • Voltage Protection – High / Low Voltage, High Temperature Protection
  • Soft Start Protection – Safeguards your expensive equipment
  • Ideal for Heavy duty Equipment

MERCURY 7.5 KVA SOHO PURE

  • Intelligent long backup model
  • Fully digitized microprocessor control LED
  • Wide input range [90V -275V inverter mode 115V -270V UPS mode]
  • Energy saving function with UPS green mode
  • Cold start function
  • Short circuit and overload protection
  • Compatible with all generators
  • Selectable  charging current 20A and 40A
  • Weight 35kg

What’s in the box:

• 1 x Mercury 7.5kva Inverter
•1 x Black Battery Cable
• 1 x Red Battery Cable
• 1 x User Manual

Good to know:

This product is sold with a one year warranty.

Mercury 15KVA AVR Single Phase

  • Phase: Single Phase
  • Over-voltage Protection; Low-voltage Protection
  • Display Model: LED / METER
  • Wide Input Voltage Range: 130V ~ 280Vac
  • Voltage Protection – High / Low Voltage, High-Temperature Protection
  • Soft Start Protection – Safeguards your expensive equipment
  • Ideal for Heavy Duty Equipment
  • 1 Year Warranty

MERCURY 5KVA SOHO PURE SINE

  • Intelligent long backup model
  • Fully digitized microprocessor control LED
  • Wide input range [90V -275V inverter mode 115V -270V UPS mode]
  • Energy-saving function with UPS green mode
  • Cold start function
  • Short circuit and overload protection
  • Compatible with all generators
  • Selectable  charging current 20A and 40A
  • Operating Temperature  0°C-40°C
  • Storage Temperature     -25°C-55°C
  • Relative Humidity  20%-95% (no condensation) <1000m, for elevation above     1000m, derate with reference to Elevation  GB7260.3-2003 4.1.1
  • Weight 35kg

What’s in the box:

• 1 x Mercury 5kva Inverter
• 1 x User Manual

Good to know:

This product is sold with a one year warranty.

Mercury 5KVA 48V Solar Hybrid

Features

  • High-frequency switching technology, compact size and lightweight
  • Pure sine wave output for a wide range of applications
  • Build-in solar charger controller with MPPT technology to optimize the power utilization (some
    models don’t have this option)
  •  Efficient DC-to-AC conversion minimizing energy loss
  •  Standby Charging Mode enables battery charging even when the unit is switched off
  •  Intelligent cooling fan control
  •  Input/ output isolated design for the maximum operation safety
  • LCD displays for detailed status
  • Configurable AC input voltage range and priority for AC or PV input
  • Supports Home Appliances / Office Equipment/ Lighting Equipment/ Motor-based Equipment
    (such as Fan, Air-Conditioner, Washing Machines etc)
  •  Input low voltage / Overload / Short circuit / Low battery alarm / Input over-voltage / Over
    temperature protection.
  • Supports both rack and wall-mount installation

Specification

Inverter Mode

  • Rated Power: 5KVA/5.0KW
  • DC Input :   48Vdc, 114A
  • AC Output:  230Vac, 50/60Hz, 21.7A
  • AC Charger Mode
  • AC Input :220 240Vac, 50/60Hz, 31.6A
  • DC Output : 54.8Vac,  35A/ 15A
  • AC Output : 230Vac, 50/ 60Hz, 21.7A

Solar Charger Mode

  • Max Charger Current 80A
  • System DC Voltage Range  48Vdc
  • Operating Voltage Range: 60  – 150Vdc
  • PV Optimal Work Voltage Range: 70 – 145 Vdc
  • Max Solar Voltage (VOC) : 150Vdc